Airmar 120WXH Weather Station Instrument
Aquamare uk
Quantity:
Airmar 120WXH Weather Station Instrument
The Airmar 120WXH Weather Station has been carefully designed, with a highly effective thermostatically controlled heating system, for operation in ice-prone areas both onshore and offshore. The heater element is designed to keep the wind channel free of snow and ice.- Ultrasonic wind readings
- Thermostatically controlled heater element
- Apparent Wind speed & angle
- Barometric pressure
- Air temperature
- Wind chill
- IPX6 Ingres protection
- Output: Via a single cable (various lengths available)
- NMEA 0183 protocol over RS-422 standard interface OR RS232 interface
- NOTE: The 120WXH CANNOT be used with an NMEA 2000® CAN BUS network
Wind Data
- Wind Speed Range:
- 0 knots to 78 knots (0 MPH to 90 MPH, 0 m/s to 40 m/s)
- Wind Speed Resolution:
- 0.1 knot (0.1 MPH, 0.1 m/s)
- Wind Speed Accuracy @ 0°C to 55°C (32°F to 131°F), no precipitation*:
- Low Wind Speeds:
- 0 -10knots; 1knot RMS +10% of reading
- (0 MPH to 11.5 MPH; 1.1MPH +10% of reading)
- (0 m/s to 5 m/s; 0.5 m/s +10% of reading)
- High Wind Speeds:
- 10-78 knots; 2 knots RMS or 5%, whichever is greater
- (11.5 MPH to 90 MPH; 2.3 MPH or 5%, whichever is greater)
- (5 m/s to 40 m/s; 1 m/s or 5%, which ever is greater)
- Wind Speed Accuracy in wet conditions**:
- 5 knots RMS (5.7 MPH RMS, 2.5 m/s RMS)
- Wind Direction Range: 0° to 360°
- Wind Direction Resolution: 0.1°
- Wind Direction Accuracy @ 0°C to 55°C (32°F to 131°F), no precipitation*:
- Low Wind Speeds (5° RMS typical):
- 4 - 10 knots (4.6 MPH to 11.5 MPH, 2 m/s to 5 m/s)
- High Wind Speeds (2° RMS typical):
- >10 knots (>11.5 MPH, >5 m/s)
- Wind Direction Accuracy in wet conditions** (8° RMS Typical):
- 8 knots (>9.2 MPH, >4 m/s)
Pitch and Roll Data
- Pitch and Roll Range / Accuracy: ±50° / <1°
Air Temperature Data
- Air Temperature Range***: -40°C to 55°C (-40°F to 131°F)
- Air Temperature Resolution: 0.1°C (0.1°F)
- Air Temperature Accuracy: ±1.1°C (±2°F)* @ >4 knots wind (>4.6 MPH wind) (>2 m/s wind)
Barometric Pressure Data
- Barometric Pressure Range: 300 mbar to 1100 mbar (24 inHg to 33 inHg, 800 hPa to 1100 hPa)
- Barometric Pressure Resolution: 0.1 mbar (0.029 inHg, 0.1 hPa)
- Barometric Pressure Accuracy: ±1 mbar (±0.029 inHg, ±1 hPa) when altitude correction is available
Operating Temperature
- Operating Temperature Range: -25°C to 55°C (-13°F to 131°F)
- Heater Operating Temperature Range: -40°C to 55°C
- Heater cycles when sensor reaches 1°C
Supply Voltage
- Supply Voltage: 12 VDC to 24 VDC
- Heater Supply Voltage: 24 VDC
- Supply Current (@ 24 VDC):
- <.1.0W (<42mA)
- Heater Supply Current (@ 24 VDC):
- <.60W (2.5A)
Data Input/Output
- Output: Via a single cable (various lengths available)
- NMEA 0183 protocol over RS-422 standard interface OR RS232 interface
- NOTE: The 120WXH CANNOT be used with an NMEA 2000® CAN BUS network
Other Specifications for the Airmar 120WXH Weather Station
- Weight: 300 grams (0.8 lb)
- Communication Interface: NMEA 0183 (RS232 or RS-422 standard & CAN)
- Mounting Thread Size on Base: Standard 1”-14 UNS (3/4” NPT optional)
- Certifications and Standards: CE, IPX6, RoHS, IEC61000-4-2, IEC60945